Transducers

Family of Transducers

C4-1 Curved Array

Special Attributes:
8 frequencies - 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications: Abdominal, Abdominal Vascular, Obstetrics, Fetal Heart, and Gynecologic.

Needle guide: Yes

C10-3 Curved Array

Special Attributes:
13 frequencies - 2D/Mode, Tissue Harmonic, Compound Harmonic Color Doppler, PW Doppler, CW Doppler, Tissue Doppler

Applications: Neonatal head, neonatal abdominal, pediatric echo, pediatric abdominal, general cardiology

Needle guide: N/A

C6-2 Curved Array

Special Attributes:
12 frequencies - 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications: Abdominal, Abdominal Vascular, OB/GYN, Fetal Heart,Technically Difficult Peripheral Vascular

Needle guide: Yes

C8-33D Curved Array

Special Attributes:
9 frequencies - 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic

Applications: 3D ultrasound imaging applications - volume rendering of 2nd & 3rd trimester fetal sonograms and Multiplanar Reconstruction (MPR) for general abdominal scans.

Needle guide: N/A

C9-3 Curved Array

Special Attributes:
13 frequencies - 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications: Obstetrics (all trimesters), Pediatric/Small Adult Abdominal Imaging, Fetal Heart and Peripheral Vascular Imaging

Needle guide: Yes

E9-4 Endovaginal

Special Attributes:
9 frequencies - 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications: First Trimester OB/GYN (uterus, ovaries)

Needle guide: Yes

E9-33D Endocavity

Special Attributes:
9 frequencies - 3D/4D (static/real-time); 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications:
Primary Applications: Endovaginal including First Trimester OB/GYN (uterus, ovaries)Surface Rendering; Multi-Planar Rendering and Tomographic Slice Imaging Mode
Secondary Applications: Endorectal including Prostate, Rectal Wall Surface Rendering; Multi-Planar Rendering and Tomographic Slice Imaging Mode

Needle guide: N/A

L8-3 Linear Array

Special Attributes:
10 frequencies - 2D/M-Mode; Color/Power/PW Doppler;Tissue Harmonic, Compound Harmonic; built-in transverse needle guide

Applications: Peripheral Vascular, Pediatric Hips, Technically Difficult Small Parts

Needle guide: Yes

L10-5 Linear Array

Special Attributes:
6 frequencies - 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic

Applications: Small Parts - Thyroid, Breast, Scrotum; Peripheral Vascular, Pediatric Hips, Superficial Parts

Needle guide: Yes - Longitudinal & Transverse

L14-5sp Linear Array

Special Attributes:
10 frequencies - 2D/M-Mode; Color/Power/PW Doppler;Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications: Intraoperative (Endarterectomy Scanning), Saphenous Vein Mapping, Neonatal, Infant, Pediatric Patients, Superficial Small Parts

Needle guide: Yes

L14-5w Linear Array

Special Attributes:
55 mm wide field-of-view. 10 frequencies - 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications: Small Parts, Thyroid, Breast, Testicular, Musculoskeletal, Vascular, Superficial, Nerve Block, Vascular Access

Needle guide: Yes - Longitudinal & Transverse

P10-4 Phased Array

Special Attributes:
8 frequencies - 2D/M-Mode; Color/Power/PW Doppler;Tissue Harmonic, Compound Harmonic

Applications: Neonatal/Pediatric Head and Abdomen, Superficial Vein mapping (Small Footprint Access), Intraoperative

Needle guide: N/A

P4-1 Phased Array

Special Attributes:
11 frequencies - 2D/M-Mode; Color/Power/PW Doppler;Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications: Small Footprint Access, Trauma (FAST Exams), Deep Abdominal, Abdominal Vascular, Renal, Aorta, Technically Difficult: OB/GYN, Fetal Heart

Needle guide: Yes

P4-1c Phased Array

Special Attributes:
14 frequencies - 2D/M-Mode; Color/Power/PW Doppler; Tissue Harmonic, Compound Harmonic, Compound Imaging

Applications: Cardiology, Transcranial Imaging/Doppler, Trauma, Deep Abdominal, Abdominal Vascular, Renal, Aorta, Technically Difficult: OB/GYN, Fetal Heart

Needle guide: N/A

P8-3TEE Phased Array

Special Attributes:
7 frequencies - 2D/M-Mode; Color/Power/PW Doppler/CW Doppler; Tissue Doppler

Applications: Adult Transesophageal echocardiography

Needle guide: N/A

C9-4t Tightly Curved Array

Special Attributes:
6 frequencies - 2D/M-Mode; Tissue Harmonic; Compound Fundamental; PW Doppler. Field of view up to 134 degrees.

Applications: Pediatric Head and Abdomen, Nerve Block, and Pediatric Cardiac. Other applications: Veterinary [small animal abdomen & cardiac]

Needle guide: N/A

L12-4v Linear Array

Special Attributes:
7 frequencies - 2D/M-Mode; Tissue Harmonic; Compound Fundamental; PW Doppler

Applications: Veterinary: Equine imaging with applications for reproductive imaging

Needle guide: N/A

A2cw Continuous Wave Transducer

Special Attributes:
2 MHz Continuous Wave (CW), non-imaging pencil probe

Applications: Cardiac imaging

Needle guide: N/A

A5cw Continuous Wave Transducer

Special Attributes:
5 MHz Continuous Wave (CW), non-imaging pencil probe

Applications: Peripheral vascular imaging

Needle guide: N/A